S7500-26XF6Y

New

Omada Pro 26-Port 10G Stackable L3 Managed Aggregation Switch with 6 25G Slots

  • 26× 10 Gbps SFP+ slots and 6× 25 Gbps SFP28 slots
  • Physical stacking for built-in redundancy and performance
  • L3 Features: OSPF, BGP, IS-IS, VRRP, PIM-SM/PIM-DM/PIM-SSM, ECMP, PBR
  • Security Strategies: Secure Boot, RADSEC, IMPB, SFTP, 802.1X, Port Security
  • Highly available with two field-replaceable power supplies,* VRRP, ERPS, BFD
  • Easy O&M: NETCONF, Configuration Rollback, Hot Patching, and RSPAN
  • Centralized cloud management via the web or the Omada app

Learn more about Omada Pro >​

 

What This Product Does

Omada Pro S7500-26XF6Y is a high-performance L3 managed switch tailored for the aggregation layer, featuring L3 routing, fast 25 Gbps wired speeds, stacking options, and redundant power supply modules. It includes 26× 10 Gbps SFP+ slots, 6× 25 Gbps SFP28 slots, physical stacking ability, and centralized management. Integrated with strong security, easy O&A, and extensive management features, S7500-26XF6Y offers a dependable networking solution for enterprises, campus, and ISPs.

High-speed Connectivity and Powerful Stacking

26× 10 Gbps SFP+ slots and 6× 25 Gbps SFP28 slots provide up to 820 Gbps switching capacity per unit. Physical stacking of up to 12 units enhances network performance and redundancy.

Abundant Layer 3 Capabilities

Comes with abundant Layer 3 routing protocols that support a scalable network, such as OSPF, BGP, IS-IS, VRRP, PIM-SM/PIM-DM/PIM-SSM, ECMP, and PBR. In complex large-scale network environments, dynamic routing protocols automatically adapt to changes in network topology and select the best transmission path based on real-time network conditions to maintain stability.

Comprehensive Security Functions

Defend against a range of network threats with Secure Boot, RADSEC, IMPB, Dynamic ARP Inspection, SFTP, 802.1X, and Secure Shell. Secure Boot protects the operating system from malicious attacks.

Highly Available

Two field-replaceable redundant power supplies* and VRRP make it an ideal choice for reliable networking architecture. ERPS supports rapid protection and recovery in a ring topology, while BFD enables sub-second failure detection for rapid routing protocol rebalancing.

Easy Operation and Maintenance

The switch can be configured and managed based on the NETCONF protocol, reducing manual configuration errors and improving software upgrade efficiency. Configuration Rollback restores previous settings if errors occur. Hot patching technology allows software defects to be fixed without device restart, preventing business interruptions.

Omada Pro Integration

Integration into the Omada Pro system brings centralized cloud management and a series of management features, such as Zero-Touch Provisioning (ZTP) and Intelligent Anomaly Detection. Omada Pro’s Software Defined Networking (SDN) platform integrates network devices, including access points, switches, and routers, providing 100% centralized cloud management. Omada Pro creates a highly scalable network—all controlled from a single interface.

Apart from central management via the web or Omada app, S7500-26XF6Y can be managed through an intuitive web GUI or industry-standard CLI, both secured with SSL or SSH encryption. SNMP (v1/v2c/v3) and RMON support provide status polling and abnormal event notifications.

HARDWARE FEATURES
Interface • 26× 1/10Gbps SFP+ Slots**
• 6× 1/10/25Gbps SFP28 Slots
• 2× USB 3.0 Ports
• 1× RJ45 Console Port
• 1× USB Type-C Console Port
• 1× RJ45 Management Port
Fan Quantity Four Field-replaceable and Hot-swappable Fans
Power Supply Two Field-replaceable and Hot-swappable Power Supply Modules*(100–240 VAC, 50/60 Hz)

*Shipping with one PSM550-AC module by default, and another field-replaceable redundant power supply requires purchasing separately.
Dimensions ( W x D x H ) 17.3 × 15.0 × 1.7 in (440 × 380 × 44 mm)
Mounting Rackmountable
Max Power Consumption 86.7 W (110 V/60 Hz)
Max Heat Dissipation 295.85 BTU/hr (110 V/60 Hz)
PERFORMANCE
Switching Capacity 820 Gbps per Unit
Stacking • Stacking Number: 12 (standalone mode)
• Stacking Port: 25G SFP28 Slot (all uplink ports can be used as stacking ports)***
• Stack Bandwidth: Up to 300 Gbps (6 stacking ports)
Packet Forwarding Rate 610.1 Mpps
MAC Address Table 128 K
Packet Buffer Memory 8 MB
Jumbo Frame 9 KB
SOFTWARE FEATURES
Quality of Service • Class of Service
- 8 Queues of Priority
- Port Priority
- IEEE 802.1p Priority
- DSCP Priority
- Queue Min-Bandwidth
- Schedule Mode (SP, WRR, SP+WRR)
• Bandwidth Control
- Rate Limit
- Storm Control
• Voice VLAN
• User-Defined OUI
• Smoother Performance
• Action for Flows
- QoS remark (802.1P Remark, DSCP Remark)
• WRED profile: 64
L3 Features • L3 Interface: 256 (IPv4,IPv6)
• Static Route: 2,048 IPv4, 1,024 IPv6
• Host Route Table: Max 15,300 entries
• IPv4 Network Router entries: 102,400 (shared with IPv6 Network Router entries)
• IPv6 Network Router entries: 51,200 (shared with IPv4 Network Router entries)
• ECMP: 256 entries, max 32 ECMP Nexthops per Destination
• Static ARP: 1,024 static entries
• Dynamic ARP: 24,576 dynamic entries
• ND: 24576
• DHCP Server: Max 64 IP pool, Max 8,000 IP entries
• DHCPv4/v6 Relay
• VRRP: Version v2/v3, Max 64 instances, Max 32 Virtual IP per instance
• OSPFv2
- OSPF Instance: 16
- Network Entries: 256 entries
- Area Entries for Stub or NSSA: 16 per instance
- Area Range Entries: 16 per instance
- Virtual-link Entries: 16 per instance
• OSPFv3
- Area Entries for Stub or NSSA: 16 per instance
- Area Range Entries: 16 per instance
• RIPv1/v2
- Network Entries: 256
- Redistribute Entries: 20
• RIPng
• IS-IS
- IS-IS Interfaces: 128
- IS-IS Area Numbers: 3
- Max Redistribute Configs: 10
- IS-IS IPV6
- IS-IS BFD
• BGP: Max 20 redistribute configs
• PIM-SM/PIM-DM/PIM-SSM
- IP Multicast Route Entries: 1K
- PIM Neighbors: 256
- Max PIM Interfaces: 128
• IGMP: Version v1/v2/v3, Max 2,048 multicast groups
• BFD: 16 template numbers, 8 session numbers
• PBR
• uRPF
L2 and L2+ Features • Link Aggregation
• Spanning Tree Protocol
• Port-based and VLAN-based Loopback Detection
• 802.3x Flow Control
• ERPS
• Mirroring
• RSPAN
• MAC Address Table
• Multicast
- IGMP Snooping
- MLD Snooping
- Multicast VLAN Registration (MVR)
- Max Multicast Table: 4K (IPv4, IPv6)
- Fast Leave
- Static Multicast Groups
- Multicast Filtering
- IGMP Snooping Authentication
Advanced Features • Automatic Device Discovery
• Batch Configuration
• Batch Firmware Upgrading
• Intelligent Network Monitoring
• Abnormal Event Warnings
• Unified Configuration
• Reboot Schedule

ISP Features:
• 802.3ah Ethernet Link OAM
• L2PT (Layer 2 Protocol Tunneling)
• Device Link Detect Protocol (DLDP)
• DDM
• sFlow
VLAN • Max 4K VLAN Group (802.1q VLAN)
• 802.1Q Tagged VLAN
• MAC VLAN Entries: 200
• Multicast VLAN
• Management VLAN
• VLAN VPN (QinQ): Max 256 entries
• GVRP
• Protocol VLAN: Protocol Template 16, Protocol VLAN 12 entries
• Voice VLAN
• Private VLAN
Security • Port Isolation
• CPU-Defend
• ARP Inspection (Dynamic ARP Inspection)
• DoS Defend
• IP-MAC-Port Binding
-1,024 Entries
- DHCP Snooping
- ARP Inspection
- IPv4 Source Guard
• IPv6-MAC-Port Binding
-1,024 Entries
- DHCPv6 Snooping
- ND Detection
- ND Snooping
- IPv6 Source Guard
• DHCP Filter
• Static/Dynamic Port Security
- Up to 64 MAC addresses per port
• Broadcast/Multicast/Unknown-unicast Storm Control
- kbps/ratio control mode
• 802.1X
- Port base authentication
- Mac base authentication
- VLAN Assignment
- MAB
- Guest VLAN
- RADIUS authentication and accountability support
• AAA (including TACACS+)
• Secure web management through HTTPS with SSLv3/TLS 1.2
• Secure Command Line Interface (CLI) management with SSHv2
• IP/Port/MAC-based access control
• Secure boot
• RADSEC
MANAGEMENT
Omada App Yes, through Omada Pro Controller
Centralized Management • Omada Pro Cloud-Based Controller
• Omada Pro Hardware Controller
• Omada Pro Software Controller
Cloud Access Yes, through Omada Pro Controller
Zero-Touch Provisioning Yes. Requiring the use of Omada Pro Cloud-Based Controller.
Management Features • Web-based GUI
• Command Line Interface (CLI) through console port, telnet
• SNMPv1/v2c/v3
- Trap/Inform
- RMON (1, 2, 3, 9 groups)
• SDM Template
• DHCP/BOOTP Client
• 802.1ab LLDP/LLDP-MED
• DHCP Auto Install
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• Password Recovery
• SNTP
• System Log
OTHERS
Package Contents • S7500-26XF6Y Switch
• Power Cord
• RJ45 Console Cable
• Quick Installation Guide
• Rackmount Kit
• Rubber Feet
System Requirements Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux.
Environment • Operating Temperature:
-5 °C to 50 °C (23 °F to 122 °F) @ 300 meters
-5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters
-5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

• Storage Temperature: -40 °C to 70 ℃ (-40 ℉ to 158 ℉)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing

*Ships with one PSM550-AC module by default, and another field-replaceable redundant power supply requires a separate purchase.

These functions require the use of the Omada Pro SDN Controller. Zero-Touch Provisioning requires the use of the Omada Pro Cloud-Based Controller.

Supports 12 units of physical stacking in standalone mode.

**No more than 6× 10G RJ45 SFP+ modules (SM5310-T) are supported. And it is recommended to have one column interval between every two 10G RJ45 SFP+ modules.

***The 25G SFP28 slots support stacking only through 25G DAC/25G SFP28 modules rather than 10G DAC/10G SFP+ modules.

From United States?

Get products, events and services for your region.