TL-SG2210MP
Switch Smart con 8 Porte Gigabit PoE+ e 2 Slot SFP | Jetstream by Omada
- Switch Gigabit PoE+ - Switch dotato di 10 porte Gigabit - 8 PoE+ e 2 SFP.
- Power Budget totale - Alimentazione PoE+ 802.3at/af-compliant fino a 150 W su tutte le 8 porte PoE+.*
- Dispositivo integrato Omada SDN* - La nuova soluzione Omada Software Defined Networking consente di gestire le reti Omada con modalità Hybrid Cloud e Full-Cloud. Integra Access Point della serie EAP, Router VPN SafeStream e Switch JetStream by Omada.
- App Omada - L'intuitiva app Omada, per dispositivi Android e iOS, consente di accedere da remoto alla rete tramite Cloud, in qualunque momento, ovunque ti trovi.
- Massima sicurezza - IP-MAC-Port Binding, ACL, Port Security, DoS Defend, Storm Control, DHCP Snooping, 802.1X, Radius Authentication, ecc.
- Ottimizzazione video/voce - Con funzionalità L2/L3/L4 QoS e IGMP snooping.
Learn more about TP-Link PoE technology >
Learn more about Omada Cloud SDN>
Software Defined Networking
Switch PoE+ per installazioni flessibili e reti altamente scalabili
Switch JetStream 10 Porte Gigabit: 2 SFP - 8 PoE+
TL-SG2210MP
-
Gestione centralizzata in Cloud
Dispositivo integrato Omada SDN
-
Funzionalità Layer L2
L2/L3/L4 QoS, ACL, IGMP Snooping
-
Massima sicurezza
LAN Area Investment Protection
-
Supporto PoE+
8 Porte PoE+ - Power budget totale 150 W*
Omada SDN - Software Defined Networking
Omada SDN è la soluzione Software Defined di TP-Link che offre soluzioni wireless e cablate ideali per strutture alberghiere e sanitarie, edifici scolastici, aziende, spazi pubblici e molto altro. Omada SDN integra una gamma completa di dispositivi - Access Point, Switch, Gateway e Hardware Controller - in una soluzione altamente scalabile con gestione Full-Cloud e Hybrid-Cloud.
Wall
Plate Outdoor Nuova interfaccia di gestione Hardware Controller Gestione Full-Cloud
Case History
-
Istituto Superiore Statale Del Rosso - Da Verrazzano
Omada Solution in ambito Education per Istituto Superiore Statale Del Rosso - Da Verrazzano. Progetto realizzato dal Partner Fans Computer.
Istituto Superiore Statale Del Rosso - Da Verrazzano
Omada Solution in ambito Education per Istituto Superiore Statale Del Rosso - Da Verrazzano. Progetto realizzato dal Partner Fans Computer.
-
Capovaticano Resort Thalasso SPA
Omada Solution in ambito Hospitality per Capovaticano Resort Thalasso SPA. Progetto realizzato dal Gold Partner Aetherna.
Capovaticano Resort Thalasso SPA
Omada Solution in ambito Hospitality per Capovaticano Resort Thalasso SPA. Progetto realizzato dal Gold Partner Aetherna.
-
Centro Vaccinale di Novegro
Omada Solution in ambito Healthcare per il Centro Vaccinale di Novegro. Progetto realizzato da Omada Partner POL-ONE S.r.l.
Centro Vaccinale di Novegro
Omada Solution in ambito Healthcare per il Centro Vaccinale di Novegro. Progetto realizzato da Omada Partner POL-ONE S.r.l.
Pol-One i partner installatori: “TP-Link ha fornito i dispositivi di rete indispensabili per la realizzazione delle postazioni informatizzate del Centro Vaccinale, che consentono di operare in modo rapido e sicuro durante tutte le fasi, dal processo di accettazione dei pazienti fino alla registrazione e certificazione dell’avvenuta vaccinazione. L’infrastruttura realizzata consente di sfruttare al massimo la velocità di connessione disponibile, snellendo notevolmente i tempi necessari a completare le pratiche amministrative.”
| Standard e protocolli | IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1x, IEEE 802.1p |
|---|---|
| Interfaccia | • 8× 10/100/1000 Mbps RJ45 Ports, all supporting PoE+ (Auto-Negotiation/Auto MDI/MDIX)• 2× 100/1000 Mbps SFP Slots |
| Media | • 10BASE-T: UTP/STP category 3, 4, 5 cable (maximum 100m)• 100BASE-TX/1000Base-T: UTP/STP category 5, 5e or above cable (maximum 100m)• 100BASE-FX: MMF, SMF• 1000BASE-X: MMF, SMF |
| Numero ventole | 1 |
| Physical security lock | Yes |
| Alimentazione | 100-240V AC, 50/60Hz |
| Porte PoE | • Standard: 802.3at/af compliant• PoE+ Ports: 8 Ports• PoE Power Budget: 150 W* |
| Dimensioni ( L x P x A ) | 294 x 180 x 44 mm |
| Tipo di montaggio | Rackmount/Desktop |
| Max. Power Consumption | • V1: 173.9 W (110 V/60 Hz) (with 150 W PD connected); 12.2 W (110 V/60 Hz) (no PD connected) • V2: 169.5 W (220 V/50Hz) (with 150 W PD connected) • V3: 175.3 W (110 V/60Hz) (with 150 W PD connected) • V4: 174.2 W (110V/60Hz) (with 150 W PD connected) |
| Max. Heat Dissipation | • V1: 41.63 BTU/h (with no PD connected); 539.35 BTU/h (with 150 W PD connected) • V2: 578.42 BTU/hr (220V/50 Hz) (with 150 W PDconnected) • V3: 597.8 BTU/hr (110 V/60 Hz) (with 150 W PD connected) • V4: 594.46 BTU/hr (110V/60Hz) (with 150 W PD connected) |
| Capacità di switching | 20 Gbps |
|---|---|
| Packet Forwarding Rate | 14.9 Mpps |
| Tabella ARP | 8K |
| Buffer (pacchetti) | 4.1 Mbit |
| Jumbo frame | 9 KB |
| QoS (Quality of Service) | • 802.1p CoS/DSCP priority • 8 priority queues • Priority Schedule Mode - SP (Strict Priority) - WRR (Weighted Round Robin) • Queue Weight Config • Bandwidth Control - Port/Flow based Rating Limit • Smoother Performance • Storm Control - Multiple Control Modes(kbps/ratio) - Broadcast/Multicast/Unknown-Unicast Control |
|---|---|
| Funzionalità L2 e L2+ | • DHCP Relay - DHCP VLAN Relay • DHCP L2 Relay • Link Aggregation - Static link aggregation - 802.3ad LACP - Up to 8 aggregation groups and up to 8 ports per group • Spanning Tree Protocol - 802.1D STP - 802.1w RSTP - 802.1s MSTP - STP Security: TC Protect, BPDU Filter/Protect, Root Protect • Loopback Detection • Flow Control - 802.3x Flow Control • Mirroring - Port Mirroring - CPU Mirroring - One-to-One - Many-to-One - Flow-Based - Ingress/Egress/Both • Device Link Detect Protocol (DLDP) • 802.1ab LLDP/ LLDP-MED |
| L2 Multicast | • 511 IPv4, IPv6 shared multicast groups • IGMP Snooping - IGMP v1/v2/v3 Snooping - Fast Leave - IGMP Snooping Querier - Static Group Config • Multicast VLAN Registration (MVR) • Multicast Filtering • MLD Snooping - MLD v1/v2 Snooping - Fast Leave - MLD Snooping Querier - Static Group Config • Limited IP Multicast (256 profiles and 16 entries per profile) |
| Caratteristiche avanzate | • Automatic Device Discovery• Batch Configuration• Batch Firmware Upgrading• Intelligent Network Monitoring• Abnormal Event Warnings• Unified Configuration• Reboot Schedule |
| VLAN | • VLAN Group - Max. 4K VLAN Groups • 802.1Q tag VLAN • MAC VLAN: 12 Entries • Protocol VLAN • GVRP • Voice VLAN |
| ACL (Access Control List) | • Support up to 230 entries • Time-Range - Time Slice - Week Time-Range - Absolute Time-Range - Holiday • Time-based ACL • MAC ACL - Source MAC - Destination MAC - VLAN ID - User Priority - Ether Type • IP ACL - Source IP - Destination IP - IP Protocol - TCP Flag - TCP/UDP Source Port - TCP/UDP Destination Port - DSCP/IP TOS • IPv6 ACL • Combined ACL • Rule Operation - Permit/Deny • Policy Action - Mirror - Rate Limit - Redirect - QoS Remark • ACL Rules Binding - Port Binding - VLAN Binding • Actions for flows - Mirror (to supported interface) - Redirect (to supported interface) - Rate Limit - QoS Remark |
| Sicurezza | • AAA • 802.1X - Port based authentication - MAC (Host) based authentication - Authentication Method includes PAP/EAP-MD5 - MAB - Guest VLAN - Support Radius authentication and accountability • IP/IPv6-MAC Binding - 512 Binding Entries - DHCP Snooping - DHCPv6 Snooping - ARP Inspection - ND Detection • IP Source Guard - 253 Entries - Source IP+Source MAC • IPv6 Source Guard - 183 Entries - Source IPv6 Address+Source MAC • DoS Defend • Static/Dynamic/Permanent Port Security - Up to 64 MAC addresses per port • Broadcast/Multicast/Unicast Storm Control - kbps/ratio control mode • Port Isolation • Secure web management through HTTPS with SSLv3/TLS 1.2 • Secure Command Line Interface (CLI) management with SSHv1/SSHv2 • IP/Port/MAC based access control |
| IPv6 | • IPv6 Static Routing and ACL• IPv6 Dual IPv4/IPv6• IPv6 Interface• Multicast Listener Discovery (MLD) Snooping• IPv6 neighbor discovery (ND)• Path maximum transmission unit (MTU) discovery• Internet Control Message Protocol (ICMP)version 6• TCPv6/UDPv6• IPv6 applications- DHCPv6 Client- Ping6- Tracert6- Telnet(v6)- IPv6 SNMP- IPv6 SSH- IPv6 SSL- Http/Https- IPv6 TFTP |
| MIBs | • MIB II (RFC1213) • Bridge MIB (RFC1493) • P/Q-Bridge MIB (RFC2674) • Radius Accounting Client MIB (RFC2620) • Radius Authentication Client MIB (RFC2618) • Remote Ping, Traceroute MIB (RFC2925) • Support TP-Link private MIBs • RMON MIB(RFC1757, rmon 1,2,3,9) |
| Omada App | Yes, through • Omada Cloud-Based Controller • OC300 • OC200 • Omada Software Controller |
|---|---|
| Centralized Management | • Omada Cloud-Based Controller• Omada Hardware Controller (OC300)• Omada Hardware Controller (OC200)• Omada Software Controller |
| Cloud Access | Yes, through • Omada Cloud-Based Controller • OC300 • OC200 • Omada Software Controller |
| Zero-Touch Provisioning | Yes. Requiring the use of Omada Cloud-Based Controller. |
| Management Features | • Web-based GUI • Command Line Interface (CLI) through telnet • SNMPv1/v2c/v3 • SNMP Trap/Inform • RMON (1,2,3,9 groups) • SDM Template • DHCP/BOOTP Client • Dual Image, Dual Configuration • CPU Monitoring • Cable Diagnostics • EEE • SNTP • System Log |
| Certificazione | CE, FCC, RoHS |
|---|---|
| Contenuto della confezione | • TL-SG2210MP• Power Cord• Installation Guide• Rackmount Kit• Rubber Feet |
| Requisiti di sistema | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10, MAC® OS, NetWare®, UNIX® or Linux. |
| Ambiente | • Operating Temperature: 0–50 ℃ (32–122 ℉); • Storage Temperature: -40–70 ℃ (-40–158 ℉) • Operating Humidity: 10–90% RH non-condensing • Storage Humidity: 5–90% RH non-condensing |
*Il calcolo del Power Budget PoEsi basa su test di laboratorio. Le prestazioni possono variare in base a limitazioni dei client e fattori ambientali.
* Verifica a questo link le funzionalità switch disponibili con Omada SDN.